OMX 333PWR

OMX 333PWR

Projection
Signalizing LED
L1, L2 Limits L1, L2 (red)
Lo, Hi Signalization, settings and errors (red/green)
Settings
Control
The instrument is controlled and set by two buttons and a DIP switch on the front panel
OM Link
Company communication interface for operation, setting and update of device firmware
OM Link program is also designed for visualization and filing of meas. values from more instruments
Instrument accuracy and functionality
Temperature coefficient
50 ppm/°C
Accuracy
0,3 % of range
Rate
0,5…10 measur./s
Overload capacity
2x; 10x (t < 30 ms) - not for > 200 V and 5 A
Linearization
linear interpolation in 25 points (only via OM Link)
Watch-dog
reset after 500 ms
Calibration
at 25°C and 40 % r.h.
Comparators
Type
Digital, menu adjustable, contact connect. < 50 ms
Mode
Hysteresis switch. point, hysteresis band "Mez ± 1/2 Hys." and time (0 ... 99.9 s) determ. switching delay
Ready output switching signals perfect status
Error output switching signals error status
Output
1x relay, switch on contact (250 VAC/30 VDC, 3A)
2x relay, switch on contact (250 VAC/30 VDC, 3 A)
1x open collector (30 VDC/100 mA)
2x open collector (30 VDC/100 mA)
Data outputs
Protocol
ASCII
Data format
8 bits + no parity + 1 stop bit (ASCII)
Rate
600…230 400 Baud
RS 485
isolated, addressing max. 31 instruments
Analogue outputs
Type
Isolated, programmable with a 16-bit D / A converter, type and range are menu selectable
Temperature coefficient
15 ppm/°C
Nonlinearity
±0,1 % of range
Rate
response to value change < 1 ms
Ranges
0...2 V, 0...5 V, 0...10 V, ±10 V, 0...5 mA, 0...20 mA, 4...20 mA
Compensation
600 Ohm/12 V
Error state
at range of 4...20mA
error message indication (<3.0 mA)
Detection of current loop interruption
Power supply
Power supply
10…30 VDC/24 VAC, ±10 %, PF > 0,4, I < 40 A/1 ms, isolated
Current draw
< 2 W/2 VA
Operating conditions
Connection
connector terminal board, cable section < 1,5 mm2
Stabilization period
within 15 minutes after switch on
Operating temperature
-20°…60°C
Storage temperature
-20°…80°C
Protection class
IP20
El. safety
EN 61010-1, A2
Dielectric strength
2,5 kVAC within 1 min. between pow. supply, input and output
2,5 kVAC within 1 min.between input and data/anal. output
Insulation resistance
for polution degree II, measuring cat. III.
power supply 550 V (ZI), 255 V (Di)*
EMC
EN 61326-1
Mechanical properties
Material
PA 66, non-inflammable UL 94 V-I (blue)
Dimensions
25 x 79 x 110 mm (w x h x d)
Installation
DIN rail, width 35 mm
Images
OMX333PWR
Dimensions and installation
To assemble the order, first select the desired instrument configuration.
OMX 333PWR-?????-??
Power supply
Any
?
Any
?
10...30 VDC/24 VAC, isolated
1
Measuring range - U
Any
?
Any
?
0...10 V/120 V
S
0...250 V/450 V
U
Measuring range - I
Any
?
Any
?
0...60 mV/300 mV
K
0...1 A/2,5 A/5 A
P
Comparators
Any
?
Any
?
No
0
1x relay
1
2x relay
2
1x open collector
3
2x open collector
4
Output
Any
?
Any
?
No
0
Analogue
1
RS 485
2
Extension
Any
??
Any
??
Standard
00
Selected combination is invalid
For the selected combination there are no devices in stock

Micro USB 2.0 cable, A-B with a length of 2 m, for connecting devices to a PC.
Double shielded 2x AWG28, supports up to 480 Mbps.

ISOLATED TRANSDUCER • USB < > OM INSTRUMENTS

Small compact transducer OM LINK USB with cable ensures safe and comfortable galvanically isolated connection between your computer and ORBIT MERRET instruments.