OMX 390PM

OMX 390PM

FAST ISOLATED TRANSMITTER • U/I > U/I

The OMX 390 model series are very fast DIN rail mountable digital transmitters with a Teach-in function.
Type OMX 390PM is a isolated transmitter. Setting of both the input and output ranges can be done conveniently by a DIP switch located on the side of the housing or from a PC via the OM Link SW. This device is based on a 32-bit processor, fast 24-bit ∆Σ ADC with PGA and 16-bit DAC, which guarantees high accuracy and excellent stability.

  • Input 0…20 mA/4…20 mA/0…10 V
  • Output 0 / 4…20 mA / 0…5 mA / 0…2 / 5 / 10 V / ±10 V
  • Rate up to 7200 meas./s
  • Teach-in, Digital filters, Tare, Linearization
  • Quick configuration by DIP switch
  • PC configurable via USB port
  • Excitation 24 VDC
  • Galvanic separation 2.5 kVAC
  • Power supply 10…30 VDC/24 VAC

 

Input
PM
Range
0…20 mA
< 200 mV
Input I
4…20 mA
< 200 mV
Input I
0…10 V
1 MOhm
Input U
External inputs
Number
2 inputs, on contact
Functions
OFF No function
HOLD Stopping measurement (option: Display - Analog output - Limits)
BLOK.K. Blocking front panel keys
TARA Tare activation
NUL. TA. Resetting tare
TAR.-NL. Aktivace Táry (<1 s) + nulov. Táry (>1 s)
T-IN.OF. Aktivace Tech-In pro Offset
SOUCET Ovládání Kumulativního měření
VZOREK Spuštění jednorázového měření
HLD.MIN HOLD - Hodnota minima*
HLD.MAX HOLD - Hodnota maxima*
HLD.M-M HOLD - Hodnota MAX-MIN*
HLD.PRM. HOLD - Průměrná hodnota*
* Hodnota se počítá z periodyí od předchozí aktivace externího vstupu
Settings
Control
Přístroj se ovládá a nastavuje dvěna tlačítky na předním panelu a DIP přepínačem na boku krabičky
Optional functions
ZAKAZ button has no function
TARA Activating function Tare
Teach-in setting the analog input range
OM Link
Company communication interface for operation, setting and update of device firmware (microUSB)
OM Link program is also designed for visualization and filing of meas. values from more instruments
Instrument accuracy and functionality
Temperature coefficient
15 ppm/°C
Accuracy
±0,01 % of range
±0,02 % z rozsahu (I)
Rate
1 000…7 200 měření/s
rychlost 400 měř/s je se FFT filtrací signálu
Overload capacity
2x; 10x (t < 30 ms)
Linearization
lineární interpolací v 100 bodech (pouze přes OM Link)
Digital filters
arithmetic mean from 2…100 measurements
floating mean from 2…30 measurements
exponential mean from 2…100 measurements
zaokrouhlení nastavení pevného kroku pro změnu hodnoty
Functions
Tare designed to reset display on non-zero input signal
Offset kompenzace rozdílu mezi měřenou a skutečnou/požadovanou hodnotou
Teach-in semiautomatic regime of input calibration
Simulace simulace vstupního signálu/funkce přístroje
Odložený start čas kdy se neprovádí měření po připojení přístroje k napájení
Math. functions
polynom, invertní polynom, logarithm, exponential, power, root
Watch-dog
reset after 500 ms
Calibration
at 25°C and 40 % r.h.
Data outputs
Type
RS 485, isolated
10/100BaseT, Modbus TCP/IP (Slave)
Protocol
MODBUS - RTU, MODBUS - TCP/IP
Data format
Format 8bit + parity + stop bit
Parity none / even / odd
Stop bit 1 / 1.5 / 2
Rate
600…230 400 Baud
100 Mbit/s
Address
MODBUS < 246 instruments
Line termination
by internal resistor 120 Ohm
Analogue outputs
Type
Isolated, programmable with a 16-bit D / A converter, type and range are menu selectable
Temperature coefficient
15 ppm/°C
Nonlinearity
±0,024 % of range
Accuray
±0,02 % full scale
±0,03 % full scale (0…5 V)
±0,05 % full scale (0…2 V / 0…5 mA)
Rate
response to value change < 160 µs
Ranges
0…2 / 5 / 10 V, ±10 V, resistive load > 1 k?
0…5 / 20 mA / 4…20 mA, comp. < 600 Ohm / V
Error state
indikace chybového hlášení
Detection of current loop interruption
Sensor excitation
Fixed
24 VDC/60 mA, isolated
Power supply
Power supply
10…30 VDC/24 VAC, ±10 %, PF > 0,4, I < 40 A/1 ms, isolated
Current draw
< 3,1 W/3,0 VA
Power supply protection
Power supply is protected by a fuse inside the instrument
Operating conditions
Connection
connector terminal board, cable section < 1,5 mm2
Stabilization period
within 5 minutes after switch on
Operating temperature
-20°…60°C
Storage temperature
-30°…85°C
Pracovní vlhkost
< 95 % r.v., nekondenzující
Protection class
IP20
El. safety
EN 61010-1, A2
Dielectric strength
2,5 kVAC within 1 min. between pow. supply and input
2,5 kVAC po 1 min. mezi vstupem a výstupem
Insulation resistance
for polution degree II, measuring cat. III.
napájení přístroje 300 V (ZI), 255 V (DI)
input, output 300 V (ZI)*
EMC
EN 61326-1
RoHS
IEC 63000 : 2018
Seismic capacity
IEC/IEEE 60980-344 ed. 1.0:2020, par 6,9
Mechanical durability
EN 60068-2-6 ed. 2:2008
Images
Dimensions and installation
Connection
To assemble the order, first select the desired instrument configuration.
OMX 390PM-?-??
Output
Any
?
Any
?
Analogue
1
Data, RS 485
2
Data, TCP/IP
3
Specification
Any
??
Any
??
Standard
00
Sig. chyby 120% max. range for AVL Moravia
10
Selected combination is invalid
Alternatives in stock
OMX 390PM-1-00In stock > 10 pcs

Micro USB 2.0 cable, A-B with a length of 2 m, for connecting devices to a PC.
Double shielded 2x AWG28, supports up to 480 Mbps.

USB ISOLATOR

Small compact isolator OM USB ISO ensures safe galvanic separation of your USB appliance.