Skip to main content

OMB 502UNI

OMB 502UNI

UNIVERSAL BARGRAPH - 2x 50 LED

The OMB 200/300/500UNI model series are simple bargraphs designed for maximum efficiency and user comfort while maintaining their low cost.
The OMB 502UNI type is a multifunction two-channel instrument with the option of configuration for 5 different types of inputs easily configurable in the instrument menu.
The instrument is based on a single-chip microcontroller with A/D converter, which secures good accuracy, stability and easy operation of the instrument.
By selecting the mode of insertion of the front plexiglass (reverse/face) you may choose the required printing of scale for vertical or horizontal design of the instrument.

  • three - color bargraph - 2x 50 LED
  • two - channel design
  • multifunction input (PM, OHM, RTD, DU)
  • digital filters, linearization
  • size of DIN 144 x 48 mm
  • power supply 10…30 V AC/DC or 80…250 V AC/DC

Options

  • comparators

 

Input
PM
Range
menu selectable
2 inputs
0…20 mA
< 1,2 V
Input 1
4…20 mA
< 1,2 V
Input 1
0…2 V
182 kOhm
Input 2
0…5 V
182 kOhm
Input 2
0…10 V
182 kOhm
Input 2
OHM
Range
menu selectable
2 inputs
0…100 kOhm
Connection
2-wire
RTD
Type
menu selectable
2 inputs
EU > 1 000 Ohm s 3 850 ppm/°C
-50°…450°C
Ni
Type
menu selectable
2 inputs
Connection
2-wire
External inputs
Number
1 input, on contact
Functions
OFF No function
HOLD Stopping measurement (option: Display - Analog output - Limits)
LOCK Blocking front panel keys
Projection
Display range
2x 50 LED
Display colour
red/green/orange
Signalizing LED
1, 2 Limits L1, L2 (red)
Display brightness
menu adjustable
Settings
Control
The device is controlled and set by five buttons located under the front panel
Selected functions can also be controlled via external inputs
Menu
LIGHT contains only items necessary for basic device settings with password access
PROFI Full device settings with password access (only via OM Link)
OM Link
Company communication interface for operation, setting and update of device firmware
OM Link program is also designed for visualization and filing of meas. values from more instruments
Instrument accuracy and functionality
Temperature coefficient
50 ppm/°C
Accuracy
±1 % of range + 1 digit
Rate
0,5/5/50/Max measur./s
Overload capacity
2x; 10x (t < 30 ms)
Wire compensation (RTD, OHM)
< 30 Ohm
Linearization
linear interpolation in 25 points (only via OM Link)
Digital filters
exponential mean from 2…100 measurements
rounding setting projection step for display
Watch-dog
reset after 25 ms
Calibration
at 25°C and 40 % r.h.
Comparators
Type
Digital, menu adjustable, contact connect. < 50 ms
Mode
Hysteresis switch. point, hysteresis band "Mez ± 1/2 Hys." and time (0 ... 99.9 s) determ. switching delay
Output
1x relay, switch on contact (250 VAC/30 VDC, 3A)
2x relay, switch on contact (250 VAC/30 VDC, 3 A)
1x open collector (30 VDC/100 mA)
2x open collector (30 VDC/100 mA)
Power supply
Power supply
10…30 V AC/DC, ±10 %, PF > 0,4, I < 45 A/1 ms, isolated
80…250 V AC/DC, ±10 %, PF > 0,4, I < 45 A/1 ms, isolated
Current draw
< 5,0 W/5,4 VA
Power supply protection
Power supply is protected by a fuse inside the instrument
Operating conditions
Connection
connector terminal board, cable section < 1,5/2,5 mm2
Stabilization period
within 15 minutes after switch on
Operating temperature
-20°…60°C
Storage temperature
-20°…80°C
Protection class
IP40 (front panel only)
El. safety
EN 61010-1, A2
Dielectric strength
4 kVAC within 1 min. between pow. supply and input
4 kVAC within 1 min. between pow. supply and data/anal. output
4 kVAC within 1 min. between input and relay output
2,5 kVAC within 1 min.between input and data/anal. output
Insulation resistance
for polution degree II, measuring cat. III.
power supply 670 V (ZI), 300 V (Di)*
input, output, PN 300 V (ZI), 150 V (Di)*
EMC
EN 61326-1
Mechanical properties
Material
Noryl GFN2 SE1, non-inflammable UL 94 V-I
Dimensions
144 x 48 x 75 mm (w x h x d)
Panel cutout
138 x 43,5 mm (w x h)
Images
Dimensions and installation
Connection
To assemble the order, first select the desired instrument configuration.
OMB 502UNI-??
Supply voltage
Any
?
Any
?
10....30 VDC/VAC
0
80.....250 VAC/VDC
1
Comparator
Any
?
Any
?
No
0
1x relay
1
2x relay
2
1x open collector
3
2x open collector
4
Selected combination is invalid
For the selected combination there are no devices in stock

Datasheets

File name File type Version Language Download
Datasheet OMB200_300_500
Datasheet OMB200_300_500
Datasheet OMB200_300_500
Katalogový list OMB200_300_500
PDF
2015.1
Download
Datasheet OMB200_300_500
Datasheet OMB200_300_500
Datasheet OMB200_300_500
Katalogový list OMB200_300_500
PDF
2014.2
Download
Datasheet OMB200_300_500
Datasheet OMB200_300_500
Datasheet OMB200_300_500
Katalogový list OMB200_300_500
PDF
2014.1
Download
Datasheet OMB200_300_500
Datasheet OMB200_300_500
Datasheet OMB200_300_500
Katalogový list OMB200_300_500
PDF
2013.2
Download
Datasheet OMB200_300_500
PDF
2013.1 ru Download
Datasheet OMB200_300_500
Datasheet OMB200_300_500
Katalogový list OMB200_300_500
PDF
2012.2
Download
Datasheet OMB200_300_500
Datasheet OMB200_300_500
Datasheet OMB200_300_500
Katalogový list OMB200_300_500
PDF
2010.1
Download
Datasheet OMB200_300_500
Datasheet OMB200_300_500
Katalogový list OMB200_300_500
PDF
2008.1
Download
Datasheet OMB200_300_500
Katalogový list OMB200_300_500
PDF
2006.2
Download
Datasheet OMB502UNI
Katalogový list OMB502UNI
PDF
2023.1
Download
Datasheet OMB502UNI
Datasheet OMB502UNI
Datasheet OMB502UNI
Katalogový list OMB502UNI
PDF
2020.1
Download
Datasheet OMB502UNI
Datasheet OMB502UNI
Datasheet OMB502UNI
Katalogový list OMB502UNI
PDF
2019.1
Download
Datasheet OMB502UNI
Datasheet OMB502UNI
Katalogový list OMB502UNI
PDF
2017.1
Download
Katalogový list OMB200_300_500
PDF
2012.1 cs Download
Katalogový list OMB200_300_500
PDF
2009.1 cs Download
Katalogový list OMB200_300_500
PDF
2007.1 cs Download
Katalogový list OMB502UNI
PDF
2016.1 cs Download
Show all ↓ Hide ↑

ISOLATED TRANSDUCER • USB < > OM INSTRUMENTS

Small compact transducer OM LINK USB with cable ensures safe and comfortable galvanically isolated connection between your computer and ORBIT MERRET instruments.