Skip to main content

OMD 202RS

OMD 202RS

4/6 digit DATA DISPLAY

The OMD 202 model series are large programmable displays designed for indoor and outdoor use with IP64 cover.
Type OMD 202RS is a data display from serial lines RS 232/485 with protocole ASCII, MESSBUS, PROFIBUS DP, MODBUS - RTU and PROFINET.
The instrument is based on a single-chip microcontroller with a multichannel 24-bit sigma-delta converter, which ensures good accuracy, stability and easy operation of the instrument.
Displays are suitable for projection of measured data in production lines and operations with legibility up to 80 m.

  • 4/6 digit programmable projection
  • input: RS 232/485
  • ASCII, MESSBUS, PROFIBUS DP, MODBUS RTU, PROFINET
  • three-color LED or high bright LED
  • digit height: 57; 100; 125 mm
  • IR control
  • digital filters, tare, linearization
  • size of DIN 96 x 48 mm
  • power supply 10…30 V AC/DC or 80…250 V AC/DC

Options

  • excitation

  • comparators

  • analog output

 

Input
RS
Input
fixed, according to order
RS 232/485
PROFIBUS DP
Protocol
ASCII
ASCII - Master
ASCII - Slave
ASCII - Universal
MESSBUS
MODBUS RTU
PROFIBUS DP
PROFINET
Format
8 bits + no parity + 1 stop bit
7 bits + even parity + 1 stop bit
Rate
300…230 400 Baud
9 600…12 MBaud (PROFIBUS)
Line termination
short circuit module socket inside the instrument
Projection
Display range
-999…9999, 3-coloured 7-segment LED
-99999…999999, 3-coloured 7-segment LED
-999…9999, single-coloured intensive LED (1200 mcd)
-99999…999999, single-coloured intensive LED (1200 mcd)
Number of characters
4 characters (only for height 100/125 mm
6 characters
Display height
57 mm, 100 mm, 125 mm
Display colour
red, green, red/green/orange
Signalizing LED
1, 2, 3, 4 Limits L1, L2, L3, L4 (red)
T Tare (green)
M Min./Max. value (green)
Description
the last two digits of the display can be used to display measured variables (only 6-digit display)
Decimal point
menu adjustable - fixed or floating
Display brightness
menu adjustable
Displayed values
Kan A Value from channel A
Fil. A Value from channel A after digital filter adjustment
Mat. Fn. Value of mathematical function
Max. Maximum value
Min. Minimum value
Settings
Control
The instrument is set and controlled by an IR remote control
Selected functions can also be controlled via external inputs
Menu
LIGHT contains only items necessary for basic device settings with password access
PROFI Full device settings with password access
USER User menu of any item, selected from LIGHT/PROFI. Access without password.
Optional functions
ZAKAZ button has no function
NUL. M.M. Resetting Min/Max vaslues
NUL. TA. Tare reset
MENU Direct access to the selected menu item
DOC. H. Temporary projection of selected values
TARA Activating function Tare
OM Link
Company communication interface for operation, setting and update of device firmware
OM Link program is also designed for visualization and filing of meas. values from more instruments
Instrument accuracy and functionality
Temperature coefficient
50 ppm/°C
Linearization
linear interpolation in 50 points (only via OM Link)
Digital filters
arithmetic mean from 2…100 measurements
floating mean from 2…30 measurements
exponential mean from 2…100 measurements
rounding setting projection step for display
Functions
Tare designed to reset display on non-zero input signal
Min/max value registration of min./max. value achieved during measurement
Peak value display shows only max. or min. values
Math. functions
polynom, 1/x, logarithm, exponential, power, root, sin x
Watch-dog
reset after 400 ms
Calibration
at 25°C and 40 % r.h.
Comparators
Type
Digital, menu adjustable, contact connect. < 30 ms
Mode
Hysteresis switch. point, hysteresis band "Mez ± 1/2 Hys." and time (0 ... 99.9 s) determ. switching delay
From-To output interval ON and OFF
Dose period, its multiples and time (0 ... 99.9 s), during which the output is active
Output
1x relay, switch on contact (250 VAC/30 VDC, 3A)
2x relay, switch on contact (250 VAC/30 VDC, 3 A)
3x relay, switch on contact (250 VAC/30 VDC, 3A)
4x relay, switch on contact (250 VAC/30 VDC, 3A)
Analogue outputs
Type
Isolated, programmable with a 16-bit D / A converter, type and range are menu selectable
Temperature coefficient
15 ppm/°C
Nonlinearity
±0,1 % of range
Rate
response to value change < 1 ms
Ranges
0...2 V, 0...5 V, 0...10 V, ±10 V, 0...5 mA, 0...20 mA, 4...20 mA
Compensation
600 Ohm/12 V, 1 000 Ohm/24 V
Error state
at range of 4...20mA
error message indication (<3.0 mA)
Detection of current loop interruption
Sensor excitation
Adjustable
5…24 VDC/max. 1,2 W
Power supply
Power supply
10…30 V AC/DC, ±10 %, PF > 0,4, I < 45 A/1 ms, isolated
80…250 V AC/DC, ±10 %, PF > 0,4, I < 45 A/2 ms, isolated
Current draw
< 22 W/22 VA
Power supply protection
Power supply is protected by a fuse inside the instrument
Operating conditions
Connection
cable bushings
connector terminal board, cable section < 1,5/2,5 mm2
Stabilization period
within 15 minutes after switch on
Operating temperature
-20°…60°C
Storage temperature
-20°…80°C
Protection class
IP64
El. safety
EN 61010-1, A2
Dielectric strength
4 kVAC within 1 min. between pow. supply and input
4 kVAC within 1 min. between pow. supply and data/anal. output
4 kVAC within 1 min. between input and relay output
2,5 kVAC within 1 min.between input and data/anal. output
Insulation resistance
for polution degree II, measuring cat. III.
power supply 670 V (ZI), 300 V (Di)*
input, output, PN 300 V (ZI), 150 V (Di)*
EMC
EN 61326-1
Mechanical properties
Material
Anodized aluminum, black
Dimensions
57 mm/6 d. 375 x 119 x 88 mm
100 mm/4 d. 465 x 181 x 88 mm
100 mm/6 d. 651 x 181 x 88 mm
125 mm/4 d. 539 x 237 x 88 mm
125 mm/6 d. 754 x 237 x 88 mm
Panel cutout
57 mm/6 d. 367 x 111 mm
57 mm/6 d. 367 x 111 mm
100 mm/6 d. 643 x 173 mm
125 mm/4 d. 531 x 228 mm
125 mm/6 d. 746 x 228 mm
Installation
Into panel
On the wall/ceiling using bracket (included)
Images
Dimensions and installation
Connection
To assemble the order, first select the desired instrument configuration.
OMD 202RS-????????-??
Power supply
Any
?
Any
?
10...30 V AC/DC
0
80...250 V AC/DC
1
Extension
Any
?
Any
?
ASCII, RS 232/485
A
MODBUS
B
PROFIBUS
C
PROFINET
D
Comparator
Any
?
Any
?
No
0
1x relay
1
2x relay
2
3x relay
3
4x relay
4
Analogue output
Any
?
Any
?
No
0
Yes (500 Ohm/12 V)
1
Yes (1 kOhm/24 V)
2
Excitation
Any
?
Any
?
No
0
Yes
1
Digit height
Any
?
Any
?
57 mm
1
100 mm
2
125 mm
3
Number of digits
Any
?
Any
?
4 digits (100/125 mm)
1
6 digits
3
Colour/type of display
Any
?
Any
?
Red (high brightness LED)
1
Green (high brightness LED)
2
Red/green/orange (7 segment LED)
3
modrá (high brightness LED)
4
Specification
Any
??
Any
??
Standard
00
Centre Pesage - expanded adjustment RS
02
Special execution pro ADAX - 67-Fxx
03
Special execution for with.n.o.p. dvoubarevné zobrazování
04
Komunikační protocol ELEN
05
Spec. with RTC and DCF (OMA Time)
06
Customised version
99
Selected combination is invalid
Alternatives in stock
OMD 202RS-1A000214-00In stock < 5 pcs
OMD 202RS-1A000231-00In stock < 5 pcs

Firmware

File name File type Version Language Download
OMD202RS-4 67-502
HEX
2020 xx Download
Show all ↓ Hide ↑

ISOLATED TRANSDUCER • USB < > OM INSTRUMENTS

Small compact transducer OM LINK USB with cable ensures safe and comfortable galvanically isolated connection between your computer and ORBIT MERRET instruments.