Skip to main content

OMR card - IN.08

OMR card - IN.08

IN.08 - 2x Input for strain gauges

Plug-in card for strain gauges measurement is fully isolated from the internal bus with a galvanic isolation also between individual inputs.
The design of the cards allows their use at any position in the device. If during the use of the device appear new requirements to increase the number of inputs or outputs, just order another card and insert it into a free slot. In this manner the device can "grow" with your requirements.
 

  • 2x Analogue input, isolated
  • range: 1…16 mV/V
  • strain gauge power supply 10 V
Input
*
Number of inputs
2 inputs, isolated
LC
Range
menu selectable
1…4 mV/V
2…8 mV/V
4…16 mV/V
Sensor excitation
10 VDC, load > 80 Ohm
Connection
6-wire
Instrument accuracy and functionality
Temperature coefficient
50 ppm/°C
Accuracy
±0,05 % of range + 1 digit
Rate
5…100 measur./s
Overload capacity
2x; 10x (t < 30 ms)
Digital filters
floating mean from 2…30 measurements
exponential mean from 2…100 measurements
Functions
Tare designed to reset display on non-zero input signal
Watch-dog
reset after 500 ms
Calibration
at 25°C and 40 % r.h.
Power supply
Power supply
5 VDC, 24 VDC
Current draw
< 1,5 W
Operating conditions
Connection
connector terminal board, cable section < 1,5 mm2
Operating temperature
-20°…60°C
Storage temperature
-20°…85°C
Protection class
IP00
El. safety
EN 61010-1, A2
Dielectric strength
2,5 kVAC within 1 min. between bus and inputs
1 kVAC within 1 min. between inputs
Insulation resistance
for polution degree II, measuring cat. III.
input, bus 300 V (ZI), 150 V (Di)*
input, input 150 V (ZI), 100 V (Di)*
EMC
EN 61326-1
Seismic capacity
IEC 980: 1993, par.6
Mechanical properties
Dimensions
65 x 98 mm
Installation
plug-in card
Images