Skip to main content

OM 653UQC

OM 653UQC

6  digit UNIVERSAL COUNTER

Type OM 653UQC is a universal inexpensive 6 digit panel counter/frequence meter/clock/timer, designed for maximum usefulness and user comfort while maintaining its fair price. The instrument is based on a single-chip microcontroller, which ensures good accuracy, stability and easy operation of the instrument.

  • 6  digit programmable projection
  • counter/frequency meter/clock/timer
  • 0,1 Hz…50 kHz; UP/DW; IRC
  • tare, preset , sum
  • digital filters, input filters
  • size of DIN 96 x 48 mm
  • power supply 10…30 V AC/DC or 80…250 V AC/DC

Options

  • excitation

  • comparators

  • data output

  • analog output

  • three-color display - 20 mm

 

Input
UQC
Input
menu selectable
on contact, TTL, NPN/PNP
0...30/300 V, comparation levels are adjustable in the menu or automatically
Input frequency
0,1 Hz…50 kHz (Mode SINGLE)
0,1 Hz…20 kHz (Mode UP/DW)
0,1 Hz…20 kHz (UP-DW)
0,1 Hz…20 kHz (Mode QUADR. - frequency)
0,1 Hz…10 kHz (Mode QUADR. - counter)
(for duty cycle 50%)
Measurement mode
SINGLE Counter/Frequency
QUADR Counter/Frequency for IRC sensor
UP/DW Counter/Frequency
UP - DW Counter/Frequency
TIME Stopwatch
RTC Clock
Time base
0,5/1/2/5/10 s
Calibration coefficient
0,00001…999999
Preset
0…999999
Input filter
out
5/40/100/1 000 Hz
Functions
Preset initial non-zero value, which is always read after resetting the instrument
Current value single setting of the initial value
Summation registration of numbers during shift operation
Time backup time is running even when the device is off (the display is off either)
External inputs
Number
1 input, on contact
Functions
OFF No function
HOLD Stopping measurement (option: Display - Analog output - Limits)
LOCK Blocking front panel keys
TARE Tare activation
SUMA Sum display
CL.SUM. Resetting sum
CLR. ST. Input clears (presets) stop-watch/counter, Stop-watch also stops
COUNT. Switching display Counter/Frequency
Projection
Display range
-99999…999999,single-coloured 7-segment LED
-999…9999, 3-coloured 7-segment LED
Display height
14 mm, 20 mm
Display colour
red, green, red/green/orange
Signalizing LED
1, 2 Limits L1, L2 (red)
T Tare (green)
M Min./Max. value (green)
Decimal point
menu adjustable - fixed or floating
Display brightness
menu adjustable, fixed, automatically
Displayed values
COUNT. Value from channel Counter
FREQ. Value from channel Frequency
Settings
Control
The device is controlled and set by five buttons on the front panel
Selected functions can also be controlled via external inputs
Menu
LIGHT contains only items necessary for basic device settings with password access
PROFI Full device settings with password access
USER User menu of any item, selected from LIGHT/PROFI. Access without password.
Optional functions
Buttons "Left", "Up", "Down", "Enter" can be assigned additional optional features
ZAKAZ button has no function
COUNT. Viewing value - channel Counter
FREQ. Viewing value - channel Frequency
CLEAR Counter reset
SET. L.1 Setting limit L1
SET. L.2 Setting limit L2
CLR. T. Tare reset
TARE Activating function Tare
CL. SUM. Summation reset
SUM. Viewing Summation
START Start for Stopwatch/watch
PAUSE Till the next touch the display will show the last value
STOP Stopping Stopwatch/Watch
CLR. ST. Stopping and resetting Stopwatch/Watch
CLEAR Resetting Stopwatch/Watch
OM Link
Company communication interface for operation, setting and update of device firmware
OM Link program is also designed for visualization and filing of meas. values from more instruments
Instrument accuracy and functionality
Temperature coefficient
50 ppm/°C
Accuracy
±0,01 % of range + 1 digit (frequency)
±0,02 % of value ±2 ms (stopwatch)
±0,02 % of value ±130 ms (RTC)
Overload capacity
2x; 10x (t < 30 ms) - not for 300 V
Linearization
linear interpolation in 25 points (only via OM Link)
Digital filters
exponential mean from 2…100 measurements
rounding setting projection step for display
input filter transmits input signal range 5…1 000 Hz
1/Fr. filter for frequency conversion to time
Functions
Tare designed to reset display on non-zero input signal
Preset initial non-zero value, which is read after each counter reset
Summation number registration upon shift operation
Time backup time is running even when the power is off (display is off either)
Current value single setting of the initial value
Time backup
Lithium cell CR 2032RV, 3V/220 mAh
Watch-dog
reset after 500 ms
Calibration
at 25°C and 40 % r.h.
Comparators
Type
Digital, menu adjustable, contact connect. < 50 ms
Mode
Hysteresis switch. point, hysteresis band "Mez ± 1/2 Hys." and time (0 ... 99.9 s) determ. switching delay
C-Pulse (L1) auto counter reset on the preset value
Once (L1) switching ON limit, however it opens only after a counter reset
On Run (L2) output is active while stopwatch is running
Output
1x relay, switch on contact (250 VAC/30 VDC, 3A)
2x relay, switch on contact (250 VAC/30 VDC, 3 A)
1x open collector (30 VDC/100 mA)
2x open collector (30 VDC/100 mA)
Data outputs
Protocol
ASCII, PROFIBUS DP
Data format
8 bits + no parity + 1 stop bit (ASCII)
Rate
300…230 400 Baud
0,0096…12 MBaud (PROFIBUS)
RS 232
isolated
RS 485
isolated, addressing max. 31 instruments
Analogue outputs
Type
Isolated, programmable with a 16-bit D / A converter, type and range are menu selectable
Temperature coefficient
15 ppm/°C
Nonlinearity
±0,1 % of range
Rate
response to value change < 1 ms
Ranges
0...2 V, 0...5 V, 0...10 V, ±10 V, 0...5 mA, 0...20 mA, 4...20 mA
Compensation
600 Ohm/12 V
Error state
at range of 4...20mA
error message indication (<3.0 mA)
Sensor excitation
Optional
5/12/17/24 VDC/mx. 2,5 W, isolated
Power supply
Power supply
10…30 V AC/DC, ±10 %, PF > 0,4, I < 40 A/1 ms, isolated
80…250 V AC/DC, ±10 %, PF > 0,4, I < 40 A/1 ms, isolated
Current draw
< 6,9 W/7,3 VA
Power supply protection
Power supply is protected by a fuse inside the instrument
Operating conditions
Connection
connector terminal board, cable section < 1,5/2,5 mm2
Stabilization period
within 15 minutes after switch on
Operating temperature
-20°…60°C
Storage temperature
-20°…80°C
Protection class
IP64 (front panel only)
El. safety
EN 61010-1, A2
Dielectric strength
4 kVAC within 1 min. between pow. supply and input
4 kVAC within 1 min. between pow. supply and data/anal. output
4 kVAC within 1 min. between input and relay output
2,5 kVAC within 1 min.between input and data/anal. output
Insulation resistance
for polution degree II, measuring cat. III.
power supply 670 V (ZI), 300 V (Di)*
input, output, PN 300 V (ZI), 150 V (Di)*
EMC
EN 61326-1
Mechanical properties
Material
Noryl GFN2 SE1, non-inflammable UL 94 V-I
Dimensions
96 x 48 x 120 mm (w x h x d)
Panel cutout
90,5 x 45 mm (w x h)
Images
Connection
Dimensions and installation
To assemble the order, first select the desired instrument configuration.
OM 653UQC-??????
Power supply
Any
?
Any
?
10...30 V AC/DC
0
80...250 V AC/DC
1
Comparators
Any
?
Any
?
No
0
1x relay
1
2x relay
2
1x OC
3
2x OC
4
Output
Any
?
Any
?
No
0
Analogue
2
Data - RS232
3
Data - RS485
4
Modbus RTU
5
Profibus DP
6
Excitation
Any
?
Any
?
No
0
Yes
1
Time backup
Any
?
Any
?
No
0
Yes
1
Display color
Any
?
Any
?
Red (14 mm)
1
Green (14 mm)
2
Red/green (20 mm)
3
Selected combination is invalid
Alternatives in stock
OM 653UQC-020101In stock < 5 pcs
OM 653UQC-020103In stock < 5 pcs
OM 653UQC-100101In stock < 5 pcs

Firmware

File name File type Version Language Download
OM 653UQC 20_62-502
HEX
OM Download
OM 653UQC 62-506
HEX
2016 xx Download
Show all ↓ Hide ↑

Software

File name File type Version Language Download
GSD OM-Profibus
GSD OM-Profibus
ZIP
2020
Download
GSDML OM-Profinet
ZIP
2020.2.33 xx Download
GSDML OM-Profinet
ZIP
2024.2.34 xx Download
Show all ↓ Hide ↑

CAD

File name File type Version Language Download
OM Krabicka
DWG
2014 xx Download
Show all ↓ Hide ↑

ISOLATED TRANSDUCER • USB < > OM INSTRUMENTS

Small compact transducer OM LINK USB with cable ensures safe and comfortable galvanically isolated connection between your computer and ORBIT MERRET instruments.