Skip to main content

OM 502LVDT

OM 502LVDT

DISPLAY FOR LVDT SENSOR

Type OM 502LVDT is a precise 5-digit panel programmable display for LVDT sensor.The basis of the device is a single-chip microcontroller and a fast converter, which guarantees the device high accuracy, stability and easy operation.

  • 5 digit programmable projection
  • input for LVDT sensor
  • accuracy 0,02 %, rate 100 measur./S
  • digital filters, tare, linearization, math.functions
  • size of DIN 96 x 48 mm
  • power supply 10…30 V AC/DC or 80…250 V AC/DC

Options

  • comparators

  • data output

  • analog output

  • measured data record

 

Input
*
Number of inputs
1 input
Projection
Display range
-99999…999999, single-coloured 14-segment LED
Display height
14 mm
Display colour
red, green
Description
the last two digits of the display can be used to display measured variables
Decimal point
menu adjustable - fixed
Display brightness
menu adjustable
Settings
Control
The device is controlled and set by five buttons on the front panel
Menu
LIGHT contains only items necessary for basic device settings with password access
PROFI Full device settings with password access
USER User menu of any item, selected from LIGHT/PROFI. Access without password.
OM Link
OM Link program is also designed for visualization and filing of meas. values from more instruments
Instrument accuracy and functionality
Temperature coefficient
50 ppm/°C
Rate
1…100 measur./s
Overload capacity
2x; 10x (t < 30 ms)
Linearization
linear interpolation in 50 points (only via OM Link)
Digital filters
arithmetic mean from 2…100 measurements
floating mean from 2…30 measurements
exponential mean from 2…100 measurements
rounding setting projection step for display
Functions
Tare designed to reset display on non-zero input signal
Min/max value registration of min./max. value achieved during measurement
Peak value display shows only max. or min. values
Math. functions
polynom, 1/x, logarithm, exponential, power, root, sin x
Data record
Measured data recording into the memory
RTC period - 1 s…1 day, time-date-display value, < 266k data, 15 ppm/°C
FAST 40 records/s, display value, < 8k data
Watch-dog
reset after 400 ms
Calibration
at 25°C and 40 % r.h.
Comparators
Type
Digital, menu adjustable, contact connect. < 30 ms
Mode
Hysteresis switch. point, hysteresis band "Mez ± 1/2 Hys." and time (0 ... 99.9 s) determ. switching delay
From-To output interval ON and OFF
Dose period, its multiples and time (0 ... 99.9 s), during which the output is active
Output
1x relay, switch-over contact (250 VAC/50 VDC, 3 A)
2x relay, switch-over contact (250 VAC/50 VDC, 3 A)
1x relay, switch on contact (250 VAC/30 VDC, 3A)
2x relay, switch on contact (250 VAC/30 VDC, 3 A)
2x bistable relay (250 VAC/30 VDC, 3A)
2x open collector (30 VDC/100 mA)
4x open collector (30 VDC/100 mA)
Data outputs
Protocol
ASCII, MESSBUS, MODBUS - RTU, PROFIBUS DP
Data format
8 bits + no parity + 1 stop bit (ASCII)
Rate
600…230 400 Baud
RS 232
isolated
RS 485
isolated, addressing max. 31 instruments
Analogue outputs
Type
Isolated, programmable with a 16-bit D / A converter, type and range are menu selectable
Temperature coefficient
15 ppm/°C
Nonlinearity
±0,1 % of range
Rate
response to value change < 1 ms
Ranges
0...2 V, 0...5 V, 0...10 V, ±10 V, 0...5 mA, 0...20 mA, 4...20 mA
Compensation
600 Ohm/12 V, 1 000 Ohm/24 V
Sensor excitation
Adjustable
5…24 VDC/max. 1,2 W
Power supply
Power supply
10…30 V AC/DC, ±10 %, PF > 0,4, I < 40 A/1 ms, isolated
80…250 V AC/DC, ±10 %, PF > 0,4, I < 40 A/1 ms, isolated
Current draw
< 8,0 W/7,8 VA
Power supply protection
Power supply is protected by a fuse inside the instrument
Operating conditions
Connection
connector terminal board, cable section < 1,5/2,5 mm2
Stabilization period
within 5 minutes after switch on
Operating temperature
-20°…60°C
Storage temperature
-20°…85°C
Protection class
IP64 (front panel only)
El. safety
EN 61010-1, A2
Dielectric strength
4 kVAC within 1 min. between pow. supply and input
4 kVAC within 1 min. between input and relay output
2,5 kVAC within 1 min.between input and data/anal. output
Insulation resistance
for polution degree II, measuring cat. III.
power supply 670 V (ZI), 300 V (Di)*
input, output, PN 300 V (ZI), 150 V (Di)*
EMC
EN 61326-1
Mechanical properties
Material
Noryl GFN2 SE1, non-inflammable UL 94 V-I
Dimensions
96 x 48 x 120 mm (w x h x d)
Panel cutout
90,5 x 45 mm (w x h)
Images
Connection
Dimensions and installation
To assemble the order, first select the desired instrument configuration.
OM 502LVDT-??????-??
Power supply
Any
?
Any
?
10...30 V AC/DC
0
80...250 V AC/DC
1
Comparators
Any
?
Any
?
No
0
1x relay (no)
1
2x normally open relay
2
2x normally open relay + 1x relay (switch-over)
3
2x normally open relay + 2x relay (switch-over)
4
2x open collector
5
4x open collector
6
2x open collector + 2x relay (switch-over)
7
2x relay (switch-over)
8
2x SSR
9
2x bistable relay
A
1x relay (switch-over)
B
Data output
Any
?
Any
?
No
0
RS 232
1
RS 485
2
MODBUS
3
PROFIBUS
4
Analogue output
Any
?
Any
?
No
0
Yes (500 Ohm/12 V)
1
Yes (1 kOhm/24 V)
2
Data recording
Any
?
Any
?
No
0
RTC
1
FAST
2
Display color
Any
?
Any
?
Red
1
Green
2
Red/green (20mm)
3
Specification
Any
??
Any
??
Standard
00
Selected combination is invalid
Alternatives in stock
OM 502LVDT-100101-00In stock < 5 pcs

Datasheets

Show all ↓ Hide ↑

User manuals

File name File type Version Language Download
Operating instructions OMProfi
Návod OMProfi
PDF
2020.3
Download
Operating instructions OMProfibus
Návod OMProfibus
PDF
2014.2.1
Download
Návod OMProfibus
PDF
2014.2.0 cs Download
Operating instructions OMProfibus
Návod OMProfibus
PDF
2010.1.2
Download
Návod OMProfibus
PDF
2007.1.0 cs Download
Operating instructions OMProfibus
PDF
2010.1.1 en Download
Operating instructions OM502
Návod OM502
PDF
2022.4.1
Download
Operating instructions OM502_2022
PDF
4v1 fr Download
Operating instructions OM502
Návod OM502
PDF
2019.4
Download
Operating instructions OM502
Návod OM502
Operating instructions OM502
Operating instructions OM502
PDF
2013.3.2
Download
Operating instructions OM502
Návod OM502
Operating instructions OM502
Operating instructions OM502
PDF
2013.3.1
Download
Operating instructions OM502
Návod OM502
Operating instructions OM502
PDF
2011.3
Download
Operating instructions OM502
Návod OM502
PDF
2010.1.6
Download
Operating instructions OM502
Návod OM502
Operating instructions OM502
Operating instructions OM502
PDF
2007.1.5
Download
Operating instructions OM502
Návod OM502
Operating instructions OM502
Operating instructions OM502
PDF
2007.1.4
Download
Návod OM502
PDF
2007.1.3 cs Download
Operating instructions OM502
Návod OM502
Operating instructions OM502
Operating instructions OM502
PDF
2007.1.2b
Download
Operating instructions OM502
Návod OM502
Operating instructions OM502
PDF
2007.1.2a
Download
Operating instructions OM502
PDF
2007.1.2 de Download
Návod OM502
Operating instructions OM502
PDF
2006.1.2
Download
Operating instructions OM502
Operating instructions OM502
PDF
2006.1
Download
Show all ↓ Hide ↑

Firmware

File name File type Version Language Download
OM 502LVDT 78-001
HEX
2019 xx Download
Show all ↓ Hide ↑

Software

File name File type Version Language Download
GSD OM-Profibus
GSD OM-Profibus
ZIP
2020
Download
GSDML OM-Profinet
ZIP
2020.2.33 xx Download
GSDML OM-Profinet
ZIP
2024.2.34 xx Download
Show all ↓ Hide ↑

CAD

File name File type Version Language Download
OM Krabicka
DWG
2014 xx Download
Show all ↓ Hide ↑